Support - Mechanical - Fuel Injector Manifolds
How to set the metering valve Set injector to wide open throttle. As pictured in the Metering Valve Schematic, the distance “X” between the center of the rod-end bearings is equal to the distance “Y” between the center of the throttle shaft and the center of the metering valve rotor (#54 shown). Note that the inlet fitting on the block is off-set to one side. Adjust the rotor so that the number is located on the wide side of the off-set. Tighten arm on the rotor and the throttle shaft. Downloads |